NANAO ELECTRIC Offical Website-Manufacture AC&DC Voltage Divider,PD discharge positioning system,Impulse Generator,Partial Discharge Detector,CT&PT Tester,VLF

NANAO ELECTRIC (WUHAN) CO.,LTD

Home > Product > Cable/Circuit/Lighting Arrester Test Device
  1. NADL-H Cable Identification Device
  2. NADL-H Cable Identification Device
  3. NADL-H Cable Identification Device

NADL-H Cable Identification Device

  • No.
  • Brand : NANAOELEC
  • Weight

Product introductionTo detect high-voltage cables charged or not, in order to overcome the construction site frequently occur due topilot error, or saw the wrong cable tie caused major power outages o

  1. Detailed information

Product introduction

To detect high-voltage cables charged or not, in order to overcome the construction site frequently occur due to

pilot error, or saw the wrong cable tie caused major power outages or personal safety incidents to ensure

construction safety, greatly improve the construction, maintenance efficiency, protection of industrial and

agricultural production and people's lives normally.

Also called name

Live cable identification device, cable identification device

The Characteristics of the products

1.High voltage cables running charged with high voltage cables or power outage identification accurate and

simple.

2.Hot Standby voltage cables for high-voltage cables and power required to carefully compare live or not

identified.

3.Complete instrument novel, portable, beautiful.

4.Operation is extremely simple.

5.Instructions clear and intuitive, with blue backlight.

6.NADL-H cable identification device designed for handheld single-handed operation, in line with user-friendly

design philosophy.

7.Sensitivity adjustable, with two kinds of highly sensitive detection probe, suitable for a variety of field.

8.A probe is suitable for running cable identification, B-type probe is suitable with the completion of the A-type

probe charged (running hot standby) power cable with identification.

The parameters of the products

1. Measuring range : 2.0m ~ 100km

2.Measurement highest resolution : 0.6m

3. Measure Minimum blind spot : 2m

4. ultra high-speed A / D sampling frequency : 100MHz automatically selected ( the highest )

5. measuring voltage pulse amplitude : ≥ 150V

6. System Error : 0.2m

Host initial measurement error : 1% ( relative )

10m ( absolute error<1km Time )

15m ( absolute error > 1km Time )

7. noiseless digital integrated fault sentinel technical indicators

1 ) Multiple hardware and software filtering, anti-noise performance

2 ) sentinel sentinel error : ≤ 0.2m

3 ) sentinel electromagnetic channel gain : ≥ 110dB (30 times )

4 ) sentinel sound channel gain : ≥ 120dB (100 times )

5 ) Advanced magnetic sound without noise interference combo sensitive one probe ( overall integrated

structure )

6 ) Advanced headphones , electronic instructions

8. high-power path signal generator main technical indicators

1 ) Output power : 8W

2 ) Output frequency : 5.000kHz/62.500kHz

Receiving frequency : 50Hz/5kHz/62.5kHz

3 ) a reliable overheating and over-current, short circuit protection

4 ) Full power automatic impedance matching 5 ) MCU control, electronic display

9. Power supply: built-in high -capacity lithium- host -ion rechargeable battery

One noiseless sentinel built high-capacity battery 9V

Handheld multi-frequency path analyzer built high-capacity battery 9V

Intelligent path signal generator 220Vac ± 10%

10. Dimensions : 380 x 320 x 240 full box structure